24 V light engineIP65 / IP67OEM & private label

Permanent Christmas Lights: the light engine, the track and the controls

Permanent lighting turned seasonal installers into year-round businesses — and the hardware behind it is a different animal from a box of string lights. We manufacture the part that decides whether a system lasts ten winters or two: the 24 V LED engine, the watertight joints and the controls. Factory-direct to installers, distributors and private-label brands.

Compare engines
System anatomy

A permanent system is three products, not one

Buyers who come from seasonal string lights usually price a permanent system as if it were a length of lights. It is not. There is a channel screwed to the structure, an engine that sits inside it, and controls that decide what the engine does. Miss any one of the three and the system either looks wrong in daylight, fails at the joints, or cannot be operated by the household.

We manufacture the engine and the controls, and we quote the channel as part of a kit when you want a single purchase order. Everything on this page is written for the people installing and reselling these systems — not for a homeowner buying a box.

Flat LED rope light engine for permanent eave lighting
24 Vconstant voltage, PWM dimmable
Layer by layer

What is inside a permanent lighting system

Six components, in the order they fail. The table also shows which of them we supply and the specification we build to.

ComponentWhat it doesWhat we supplyTypical specification
Aluminium channel / trackHolds the engine, spreads heat, defines the daytime look of the eaveMatched to our engine and supplied as part of the kit on requestAnodised 6063, 1 m / 2 m lengths, clips, end caps, diffuser options
Light engineThe part that actually emits — sits inside the channelMade in our own workshop: 24 V neon flex, flat rope, COB strip8–14 W/m · IP65 / IP67 · 2700–6500 K · RGB / RGBW / DMX
Joints and connectorsThe number-one cause of callbacks on permanent systemsFactory-terminated, over-moulded or IP68 screw connectorsPull-tested and sample-checked per production batch
Drivers and power injectionHolds voltage up along long eaves and rooflines24 V constant-voltage dimmable drivers, 100–600 WPF > 0.9 · flicker-free dimming · IP67 versions
ControlsScene, schedule, colour and zoningRF remote, Wi-Fi / BLE controller, DMX512 interface4–8 zones typical · app + open API on request
Mounting hardwareWhat keeps the channel on the fascia for a decadeStainless screws, UV-stable clips, standoffs, cable glandsColour-matched to the channel on request
Engine selection

Four engines, four different jobs

The engine sets the bend radius, the power per metre and the price. Most residential programmes run on 360° round neon flex; volume commercial fascia runs on flat rope; animated facades need addressable pixels.

EngineProfile & bendingPowerMin. bend radiusBest for
360° round neon flexRound cross-section, bends in any direction8–10 W/m5 cmRooflines, curves, soffits, columns — the default for residential retrofits
Flat 2-wire ropeFlat profile, top-bend only6–8 W/m3 cmStraight runs, commercial fascia, budget-sensitive volume programmes
Flat 3-wire ropeFlat profile with a return circuit8–10 W/m3 cmLonger single runs before an injection point is needed
DMX512 addressable stripIndividually controlled pixels12–14.4 W/m5 cmCommercial facades, animated scenes, landmark retail frontage

All engines: 24 V DC · 2700 / 3000 / 4000 / 5000 / 6500 K · RGB, RGBW or addressable · IP65 standard, IP67 on request · UV-stabilised jacket.

Voltage drop

Why permanent systems run on 24 V, not 12 V

Drop along a run rises with the square of the length and falls with the square of the supply voltage. Doubling from 12 V to 24 V therefore buys roughly four times the run before the far end starts to dim — which is exactly what matters on a 20 m roofline with one driver in the garage.

The table is a rule of thumb at a 10% drop, one feed, 1.0–1.5 mm² copper. Every project still gets calculated against the actual engine and the actual cable route before we ship.

Sizing a run right now?

Send the metres, the watts per metre and the supply voltage — we return the injection plan and the driver rating the same working day.

Read the power & transformer guide
Engine draw24 V max run12 V max runFeed cable
6 W/m16 m8 m2 × 1.0 mm²
8 W/m14 m7 m2 × 1.0 mm²
12 W/m11 m5.5 m2 × 1.5 mm²
Long term

What actually goes wrong — and how the build answers it

Permanent lighting is judged seasons after the van leaves, not on the day of install. These are the five failures that generate warranty calls, and what we do about each one.

FailureOur answer
Cheap PVC yellows in two summersUV-stabilised jacket compound and a colour-stability test report; we quote the UV grade explicitly rather than assume it.
Moisture gets into the joint, not the LEDEvery joint is made in the factory — over-moulded or IP68 screw type — rather than on the ladder. Field-cut ends get a sealed end cap and gland.
Adhesive backing fails and the strip sagsWe do not rely on tape. The engine sits in an aluminium channel fixed with clips and stainless screws, so thermal cycling cannot peel it off.
Drivers cook in a closed soffitDriver sizing uses the 80% continuous-load rule and the enclosure temperature, not the nameplate wattage alone.
The app is abandoned and the system is orphanedStandard 24 V constant-voltage output and PWM / 0-10 V / DMX dimming, so a replacement controller from any supplier still works.
Quotation

What to send us for a price

The quotes that take longest to close are the ones missing three of these. Send all twelve and the reply is a costed kit, not a question.

  • Total linear metres and how many separate runs (zones)
  • Mounting surface — wood fascia, aluminium soffit, render, stone, glass
  • Height above ground and whether ladders or a lift are needed
  • Voltage available on site (120 V / 230 V) and where the drivers will live
  • Colour temperature for everyday use, and the holiday scene you want
  • Whether the system must run off one controller or several zones
  • App, remote, wall switch or DMX — and who integrates it
  • IP requirement and the climate: coastal salt, desert heat, snow load
  • Channel profile and finish, or a drawing of the profile you already use
  • Branding: your logo on the channel, the box, the app splash screen
  • Target unit cost and annual volume for the first two seasons
  • Destination port and the month you need the goods on the water
Compliance & capacity

Documents your installer or retailer will ask for

  • CE Declaration of Conformity and RoHS report
  • IP65 / IP67 test report for the engine and the joints
  • Photometric and colour-consistency data (CCT bin, CRI)
  • Driver datasheet with PF, THD and dimming curve
  • Wiring diagram and injection plan for the project
  • 2-year warranty statement on engine and driver
  • Pre-shipment inspection photos and a packing list per carton
  • 5,000 m² plant · 180,000 sets per month · 1,200+ containers shipped

CE and RoHS on engine and driver · UL / ETL listed components available on request for North America · UKCA documentation for the UK · IP65 / IP67 test reports per batch on request.

FAQ

Questions installers and distributors ask

Do you supply the whole system or only the light engine?
Both, depending on how you buy. Installers usually take the engine, factory-terminated joints, drivers and controllers from us and source the aluminium channel locally. Distributors and private-label brands take complete kits — channel, engine, joints, driver, controller, mounting hardware — packed under their own brand.
What is the MOQ on permanent lighting?
100 m per colour and profile for the light engine — 30 m on a trial order; 50 pcs for drivers and controllers, 10 pcs on a trial; and 5 m cut lengths for samples. Complete kits are quoted per project rather than against a fixed MOQ, because the mix of channel, engine and controls changes with every roofline.
Which colour temperature should I stock for everyday use?
2700–3000 K warm white is what reads as residential and is what most US installers lead with. 4000 K suits commercial fascia and parking structures. We also build 5000–6500 K, and dual-white engines that switch between warm and cool from the same controller.
Can I use my own controller or smart-home system?
Yes. Our engines are 24 V constant voltage with PWM dimming, so any controller rated for the load works — including Shelly, Fibaro, Home Assistant relays and DMX interfaces. Where you buy our controller, we publish the protocol so your integrator is not locked in.
What warranty do you give on a permanent system?
Two years on the engine and driver under normal use, counted from the delivery date. Claims are handled by replacement length, not by credit note, so the installer can finish the job instead of refunding it.
How long is production and what is the lead time to the US?
15–20 days for standard engines and drivers from stock colours; 25–35 days where the channel profile or jacket colour is customised. Add 30–38 days ocean freight to a US East or West Coast port, or 5–7 days by air for sample and small kit orders.
Is permanent lighting actually a better business for installers than seasonal string lights?
It is a different business. Seasonal work is a one-off invoice per house per year; permanent systems are sold once and then earn service, extension and control-upgrade revenue for a decade. The trade-off is that the installation is slower, the skill bar is higher and the hardware cost sits on your books before the customer pays — which is why engine quality and joint reliability decide whether the model works.
Can the same system be used for Christmas scenes and everyday lighting?
That is the point of it. A dimmable 2700–3000 K warm-white engine with zoning gives you architectural accent lighting for eleven months and a holiday scene in December, from one installation. RGB and RGBW engines add colour scenes for holidays and events without a second product.
Next step

Tell us the roofline, we will cost the system

Send the linear metres, the mounting surface and the colour scene you are selling. You get back a costed kit — engine, joints, driver, controller — with an injection plan and a lead time, within 12 working hours.